FS#8513 — p19-72/p19-77
Scheduled Maintenance Report for Network & Infrastructure
Completed
p19-72 is currently connected to p19-2 and p19-77 is connected to p19-7. We are experiencing a load balancing issue on long connections where the packet is redirected from one side to another. We will try to fix the issue by adding 2 AX to each router and we hope that the packet that will go through p19-7/p19-77 and that will switch to p19-2 still arrive on p19-77.

Update(s):

Date: 2013-04-22 23:36:18 UTC
This seems to be working:
1) the same IP SRC/PORT SRC gets always to the same AX

2) an upload of the 2H has succeed

real 109m16.779s
user 0m0.100s
sys 0m0.193s


We are carrying on tests.

Date: 2013-04-22 23:34:48 UTC
We have connected the 2 AX on the 2 routers.
We are now testing if a very very long connection
to a shared cuts off or continues to perform even
if the ECMP switches the routing from a router to another.
Posted Apr 22, 2013 - 14:16 UTC