FS#2654 — FS#6616 — Lille dslam loop
Attached to Project— ADSL / SDSL
Modernization | |
Backend / Core | |
CLOSED | |
![]() |
We are migrating the escalations of the router 6k to the 2 n5.
This afternoon, we are going to interrupt a side to plug it on the fisrt n5.
Tomorrow morning at 7:00, we are going to do a shutdown on the ports on the 6k
and to mount them on the n5. It is expected to have 1 minute of interruption. No synchronisation
of adsl/sdsl.
We are going to see if everything is ok. In case of problems, a roll back in 1 minute
is posible.
Tomorow during the day, we will unplug the interrupted side of 6k in order
to put the second n5 and we put on the securisation.
Date: Saturday, 21 April 2012, 02:55AMThis afternoon, we are going to interrupt a side to plug it on the fisrt n5.
Tomorrow morning at 7:00, we are going to do a shutdown on the ports on the 6k
and to mount them on the n5. It is expected to have 1 minute of interruption. No synchronisation
of adsl/sdsl.
We are going to see if everything is ok. In case of problems, a roll back in 1 minute
is posible.
Tomorow during the day, we will unplug the interrupted side of 6k in order
to put the second n5 and we put on the securisation.
Reason for closing: Done
We are going to interrupt a side on 6k.
We will proceed to cutting off the port-channel and the interface on 6K then switch towards nexus.
migration successfully completed, customers can ping nexus.
We are ending switching tasks this afternoon. We are going to re-cable the rest of the fibres on the second nexus. Tonight at 00h00 we are engaging security.
We are starting to switch to the 2nd nexus and engage security.
Ports are up on the 2nd n5.
A single port is not yet mounted, we are checking the link physically.
A problem in the garter.
All NRA in Lille are secured on the 2 n5.