FS#12760 — FS#17641 — fra-1/5-n7

Attached to Project— Network
Maintenance
Backbone EU
CLOSED
100%
Following the replacement of fra-1/5-n7 chassis by nexus7710 we have the standby sup which remained in a fail state.
We replaced by the standby SUP by an RMA but the problem remains.

Cisco has given us a last chance procedure:
1. Copy running-config to bootflash:
2. Write erase
3. Reload standby supervisor.
4. Copy running-config startup-config

We'll start with fra-1-n7.
Date:  Wednesday, 20 April 2016, 17:08PM
Reason for closing:  Done
Comment by OVH - Wednesday, 20 April 2016, 17:07PM

It's done, but the problem remains.

Mod Online Diag Status
--- ------------------
1 Pass
2 Pass
5 Pass
6 Fail
7 Pass
8 Pass
9 Pass
10 Pass